Notifications
You must be signed in to change notification settings - Fork 6
Expand file tree
/
Copy pathnet.pyi
More file actions
406 lines (323 loc) · 19 KB
/
Copy pathnet.pyi
File metadata and controls
406 lines (323 loc) · 19 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
"""
Function:
This feature is related to the network and provides interfaces of configuring and querying the information of the network mode, such as getting the network registration status and setting the network searching mode.
Note: It is recommended that you should configure the APN information of the corresponding operator when using SIM cards of different operators. If the APN information is not configured or the configuration is incorrect, the module may not register on the network.
See dataCall.setPDPContext for methods of how to configure the APN information.
Descriptions taken from:
https://python.quectel.com/doc/quecpython/API_reference/en/iotlib/net.html
"""
from typing import Union
def csqQueryPoll():
"""This method gets the signal strength.
Note: Range of the value of signal strength: 0–31. The higher the value, the better the signal strength.
:return: Value of CSQ signal strength - Successful execution; -1 - Failed execution; 99 - Error.
"""
def getCellInfo():
"""This method gets the information of neighbour cells.
Note: This interface will block for 3–5 seconds when searching for cells. In areas without signals, the blocking time will be longer.
:return: List of the information of three network modes (GSM, UMTS, LTE) - Successful execution.;
-1 - Failed execution.
An empty list - The information of the corresponding network mode is empty.
([(flag, cid, mcc, mnc, lac, arfcn, bsic, rssi)], [(flag, cid, licd, mcc, mnc, lac, uarfcn, psc, rssi)], [(flag, cid, mcc, mnc, pci, tac, earfcn, rssi, rsrq, sinr),...])
Descriptions of GSM network mode:
Parameter Description
flag Cell type. Range: 0–3. 0: Current serving cell. 1: Neighbour cell. 2: Intra-frequency neighbour cell. 3: Inter-frequency neighbour cell.
cid Cell ID in GSM network. 0 indicates empty. Range: 0–65535.
mcc Mobile Country Code. Range: 0–999.
Note: For EC100Y/EC600S/EC600N/EC600E/EC800E/EC200A/EC600M/EC800M series module, the value needs to be converted to hexadecimal. For example, Decimal number 1120 is 0x460 in hexadecimal in which 460 indicates MCC460. For other series modules, this value is in decimal format.
mnc Mobile Network Code. Range: 0–99.
lac Location Area Code. Range: 1–65534.
arfcn Absolute Radio Frequency Channel Number. Range: 0–65535.
bsic Base Station Identification Code. Range: 0–63.
rssi In GSM network, this value indicates Rx level and describes the received signal strength. 99 indicates unknown or undetectable.
RSSI = RXLEV - 111. Unit: dBm. Range of RXLEV: 0–63. Range of RSSI: -111 to -48 dBm.
Descriptions of UMTS network mode:
Parameter Description
flag Cell type. Range: 0–3. 0: Current serving cell. 1: Neighbour cell. 2: Intra-frequency neighbour cell. 3: Inter-frequency neighbour cell.
cid Cell identity in UMTS network mode. Cell identity = RNC_ID × 65536 + Cell_ID. Range of cell identity: 0x0000000–0xFFFFFFF (The cell identity is 28 bits). It means that the first two bytes of cell identity indicate RNC_ID and the last two bytes indicate Cell_ ID. Range of Cell_ID: 0–65535.
lcid URA ID. Range: 0–65535. 0 indicates that the information does not exist.
mcc Mobile Country Code. Range: 0–999.
mnc Mobile Network Code. Range: 0–99.
lac Location Area Code. Range: 1–65534.
uarfcn UTRA Absolute Radio Frequency Channel Number. Range: 0–65535.
psc Primary Scrambling Code. This parameter determines the primary scrambling code of the scanned cell. Range: 0–511.
rssi In UMTS network, this value indicates received signal code power (RSCP), that is CPICH/PCCPCH.
RSSI = RSCP - 115. Unit: dBm. Range: -121 to -25 dBm.
Descriptions of LTE network mode:
Parameter Description
flag Cell type. Range: 0–3. 0: Current serving cell. 1: Neighbour cell. 2: Intra-frequency neighbour cell. 3: Inter-frequency neighbour cell.
cid Cell identity, also called E-UTRAN cell identifier (ECI) in LTE network. ECI = eNodeB ID × 256 + Cell ID. Range: 0x0000000–0xFFFFFFF (The cell identity is 28 bits). The first 20 bits indicate eNodeB ID. The last 8 bits indicate LTE Cell ID.
mcc Mobile Country Code. Range: 0–999.
mnc Mobile Network Code. Range: 0–99.
pci Physical-layer cell identity. Range: 0–503.
tac Tracking Area Code. Range: 0–65535.
earfcn E-UTRA Absolute Radio Frequency Channel Number. Range: 0–65535.
rssi In LTE network, RSSI indicates all received signal strength. Range: -140 to -44. Unit: dBm.
Note: All series modules cannot get RSSI currently but use RSRP, excluding BC25/BG95 series module.
RSRP indicates received effective signal strength. Range: -140 to -44. Unit: dBm.
rsrq Reference signal receiving quality (RSRQ) of the LTE network. Range: -20 to -3.
Note: Theoretically, RSRQ ranges from -19.5 to -3. But due to the problem of calculation method, the supported RSRQ ranges from -20 to -3.
Currently, it is meaningful to get this parameter only for BC25/BG95/EC600E/EC800E series module. This parameter is meaningless for other modules.
"""
def currentCellInfo():
return getCellInfo()
"""
The customer wants to use it in this way, so it was encapsulated.
"""
def getConfig():
"""This method gets the current network mode and roaming configuration.
BC25 series module does not support this method.
BG95-M1 series module only supports CAT-M network mode.
BG95-M2 series module only supports two network modes: CAT-M and CATNB.
BG95-M3/M8 series module supports three network modes: CAT-M, CATNB and GSM.
:return: -1 - Failed execution; A tuple containing the current preferred network mode and roaming enabling status - Successful execution.
"""
def setConfig(mode, roaming):
"""This method sets the network mode and roaming configuration.
roaming is an optional parameter, which can be omitted for unsupported module models.
BC25 series module does not support this method.
EC200U/EC600U/EG915U/EG912U series module does not support the configuration of roaming parameters and only supports network modes GSM, GSM_LTE (automatic) and GSM_LTE (LTE preferred).
EC600E/EC800E series module only supports LTE network mode.
:param mode: Integer type. Network mode. See the above table of network modes for details.
:param roaming: Integer type. Roaming switch. Optional parameter (0: Disable, 1: enable).
:return: 0 - Successful execution; -1 - Failed execution.
"""
def getNetMode():
"""This method gets the network configuration mode.
:return: -1 - Failed execution; A tuple (selection_mode, mcc, mnc, act) - Successful execution
Parameter Type Description
selection_mode Integer Method. 0 - Automatically. 1 - Manually.
mcc String Mobile Country Code.
mnc String Mobile Network Code.
act Integer ACT mode of the preferred network.
Enumeration values of ACT modes:
Value ACT Mode
0 GSM
1 COMPACT
2 UTRAN
3 GSM wEGPRS
4 UTRAN wHSDPA
5 UTRAN wHSUPA
6 UTRAN wHSDPA HSUPA
7 E UTRAN
8 UTRAN HSPAP
9 E UTRAN CA
10 NONE
Enumeration values of ACT modes of BG95 series module:
Value ACT Mode
0 GSM
1 GSM COMPACT
2 UTRAN
3 GSM wEGPRS
4 UTRAN wHSDPA
5 UTRAN wHSUPA
6 UTRAN wHSDPA HSUPA
7 E_UTRAN
8 UTRAN HSPAP
9 E_UTRAN_CA
10 E_UTRAN_NBIOT
11 E_UTRAN_EMTC
12 NONE
"""
def getSignal(sinrEnable=0):
"""This method gets the detailed signal strength.
sinrEnable is an optional parameter, which can be omitted for the unsupported modules. If you do not enter this parameter, sinr won't be got by default.
All Quectel series modules support to get sinr, excluding BC25 series module.
:param sinrEnable: Integer type. Optional parameter. Enable or disable to get SINR.
Value Description
0 Disable to get SINR
1 Enable to get SINR
:return: -1 - Failed execution; A tuple containing (GW, LTE) - Successful execution
([rssi, bitErrorRate, rscp, ecno], [rssi, rsrp, rsrq, cqi, sinr])
Descriptions of GSM/WCDMA :
Parameter Description
rssi In GSM and WCDMA network, this value indicates Rx level and describes the received signal strength. 99 indicates unknown or undetectable.
RSSI = RXLEV - 111. Range of RXLEV: 0–63. Unit: dBm.
bitErrorRate Bit error rate. Range: 0–7. 99 indicates unknown or undetectable.
rscp Receive Signal Channel Power. Range: -121 to -25 dBm. 255 indicates unknown or undetectable.
ecno Range: -24–0. 255 indicates unknown or undetectable.
Descriptions of LTE :
Parameter Description
rssi Received Signal Strength Indicator. Range: -140 to -44 dBm. 99 indicates unknown or undetectable.
rsrp Reference Signal Receiving Power. Range: -140 to -44 dBm. 99 indicates unknown or undetectable.
rsrq Reference Signal Receiving Quality. Range: -20 to -3 dBm. The higher the value, the better the reference signal received quality. 255 indicates unknown or undetectable.
cqi Channel Quality Indication. 255 indicates unknown or undetectable.
sinr Signal to interference plus Noise Ratio. Range: -10–40 dBm. 255 indicates unknown or undetectable.
"""
def nitzTime():
"""This method gets the current base station time, which is the time issued by the base station when the module boots and registers on the network successfully.
:return: -1 - Failed execution; A tuple (date, abs_time, leap_sec) containing the base station time and corresponding timestamps and leap seconds (0 indicates that the current base station time is unavailable.) - Successful execution
Parameter Type Description
date String Base time. The part of the time zone varies with module models. See the example below for details.
Please use setTimeZone(offset) and getTimeZone() of utime feature if you need to set and get the time zone.
The unit of these two interfaces is hour for different modules. See utime for details.
abs_time Integer Absolute seconds of the base station time.
leap_sec Integer Leap seconds.
"""
def operatorName():
"""This method gets the operator information of the current network registration.
:return: -1 - Failed execution; A tuple (long_eons, short_eons, mcc, mnc) containing the operator information of the current network registration - Successful execution
Parameter Type Description
long_eons String Operator's full name.
short_eons String Operator's name abbreviation.
mcc String Mobile Country Code
mnc String Mobile Network Code
"""
def getState():
"""This interface gets the network registration information.
:return: -1 - Failed execution; A tuple ([voice_state, voice_lac, voice_cid, voice_rat, voice_reject_cause, voice_psc], [data_state, data_lac, data_cid, data_rat, data_reject_cause, data_psc]) containing the information of the phone and network registration - Successful execution
"""
def getCi():
"""This method gets neighbour cells. The result gotten by this interface is the collection of cell IDs in the result gotten by net.getCellInfo().
:return: An array [id, ……, id] containing cell IDs. List type. The number of array members is not fixed, and different locations, signal strength, and other factors may lead to different results. - Successful execution; -1 - Failed execution.
"""
def getServingCi():
"""This method gets the serving cell ID. The result gotten by this interface is the collection of cell IDs in the result gotten by net.getCellInfo().
:return: Serving cell ID - Successful execution; -1 - Failed execution.
"""
def getMnc():
"""This method gets MNC of the neighbour cell ID.
The result gotten by this interface is the collection of MNCs in the result gotten by net.getCellInfo().
:return: An array [mnc, ……, mnc] containing mnc of cells. List type. The number of array members is not fixed, and different locations, signal strength, and other factors may lead to different results. - Successful execution; -1 - Failed execution.
"""
def getServingMnc():
"""This method gets MNC of the serving cell.
The result gotten by this interface is the collection of MNCs in the result gotten by net.getCellInfo().
:return: mnc of the serving cell - Successful execution; -1 - Failed execution.
"""
def getMcc():
"""This method gets MCCs of the neighbour cells.
The result gotten by this interface is the collection of MCCs in the result gotten by net.getCellInfo().
For EC100Y/EC600S/EC600N/EC600E/EC800E/EC200A/EC600M/EC800M series module, the value needs to be converted to hexadecimal. For example, Decimal number 1120 is 0x460 in hexadecimal in which 460 indicates MCC460. For other series modules, this value is in decimal format.
:return: An array [mnc, ……, mnc] containing mnc of cells. List type. The number of array members is not fixed, and different locations, signal strength, and other factors may lead to different results. - Successful execution; -1 - Failed execution.
"""
def getServingMcc():
"""This method gets MCC of the serving cell.
The result gotten by this interface is the collection of MCCs in the result gotten by net.getCellInfo().
For EC100Y/EC600S/EC600N/EC600E/EC800E/EC200A/EC600M/EC800M series module, the value needs to be converted to hexadecimal. For example, Decimal number 1120 is 0x460 in hexadecimal in which 460 indicates MCC460. For other series modules, this value is in decimal format.
:return: mcc of the serving cell - Successful execution; -1 - Failed execution.
"""
def getLac():
"""This method gets LACs of the neighbour cells.
The result gotten by this interface is the collection of LACs in the result gotten by net.getCellInfo().
:return: An array [lac, ……, lac] containing lac of cells. List type. The number of array members is not fixed, and different locations, signal strength, and other factors may lead to different results. - Successful execution; -1 - Failed execution.
"""
def getServingLac():
"""This method gets LACs of the serving cells.
The result gotten by this interface is the collection of LACs in the result gotten by net.getCellInfo().
:return: lac of the serving cell - Successful execution; -1 - Failed execution.
"""
def getModemFun():
"""This method gets the current work mode.
:return: The current work mode of the module - Successful execution; -1 - Failed execution.
Mode Description
0 Minimum functionality. In this mode, the entire radio frequency network protocol stack is completely closed, and the power supply to the SIM card is stopped.
1 Full functionality (default). In this mode, the device can send and receive RF signals.
4 Disable UE from both transmitting and receiving RF signals.
"""
def setModemFun(fun, rst=0):
"""This method sets the current work mode of the module.
:param fun: Integer type. Work mode of the module.
Mode Description
0 Minimum functionality. In this mode, the entire radio frequency network protocol stack is completely closed, and the power supply to the SIM card is stopped.
1 Full functionality (default). In this mode, the device can send and receive RF signals.
4 Disable UE from both transmitting and receiving RF signals.
:param rst: Integer type. Reboot flag. Optional parameter.
Value Description
0 Do not reboot the module after setting the current work mode (default).
1 Reboot the module after setting the current work mode.
:return: 0 - Successful execution; -1 - Failed execution.
"""
def setBand(netRat, gsmBand, bandTuple):
"""This method sets the required band, that is, lock the band specified by the user if the module supports this method.
Currently, BG95 series module/EG912N-ENAA module supports this method.
BG95 series module does not support the band of LTE network.
EG912N-ENAA module only supports the band of GSM network and LTE network.
:param netRat: Integer type. Network mode. It indicates the kind of network mode whose band is to be set.
:param gsmBand: Integer type. The band value of GSM network. See the band value comparison table above.
:param bandTuple: The band value of other network modes excluding GSM network and it is a tuple containing 4 elements (band_hh, band_hl, band_lh, band_ll), each of which cannot exceed 4 bytes.
:return: 0 - Successful execution; -1 - Failed execution.
"""
def getBand(netRat):
"""This method gets the band value in the current network mode.
Currently, BG95 series module/EG912N-ENAA module supports this method.
BG95 series module does not support the band of LTE network.
EG912N-ENAA module only supports the band of GSM network and LTE network.
:param netRat: Integer type. Network mode. It indicates that the band of which network mode you want to set.
RAT Value Description
0 GSM network
1 LTE network
2 Cat M network
3 NB-IoT network
:return: Band value in hexadecimal.
"""
def bandRst():
"""This method restores the initial set value of the band.
Note: EG912N-ENAA series module supports this method.
:return: 0 - Successful execution; -1 - Failed execution.
"""
def setCallback(handler: callable) -> int:
"""Register a network event callback function
:param handler: Python callable object
:return: 0 - Successful execution; -1 - Failed execution.
"""
"""
Network Timer and Status Configuration
AT command interface for network parameters.
"""
def getT3402() -> Union[str, int]:
"""Get T3402 timer value
:return:
str - Timer value string on success
-1 - Error occurred
"""
def getT3412() -> Union[str, int]:
"""Get T3412 timer value
:return:
str - Timer value string on success
-1 - Error occurred
"""
def getT3324() -> Union[str, int]:
"""Get T3324 timer value
:return:
str - Timer value string on success
-1 - Error occurred
"""
def getTeDRX() -> Union[str, int]:
"""Get eDRX configuration
:return:
str - Configuration string on success
-1 - Error occurred
"""
def getTPTW() -> Union[str, int]:
"""Get Paging Time Window value
:return:
str - Paging window string on success
-1 - Error occurred
"""
def getqRxlevMin(flag: int = None) -> Union[str, int, tuple]:
"""Get qRxlevMin parameters
:param flag: Optional flag (0 or 1)
When 1, returns tuple of three values
:return:
str - Single value when flag=None or 0
tuple - (qRxlevMin, qRxlevMinCE, qRxlevMinCE1) when flag=1
-1 - Error occurred
:raises ValueError: If flag is not 0 or 1
"""
def getRejectCause() -> Union[str, int]:
"""Get network reject cause value
:return:
str - Reject cause string on success
-1 - Error occurred
"""
def causeInfo(mode: int = None) -> int:
"""Get or set cause info configuration
:param mode: Optional configuration mode (0 or 1)
When omitted, returns current mode
:return:
Current mode (0 or 1) when getting
0 if success when setting
-1 if error occurred
:raises ValueError: If mode is not 0 or 1 when setting
"""